Abstract: Sufficient cover is required for the reinforcement in concrete structures for protection against corrosion. Though several codes of practices have specified minimum cover for various climatic conditions, it is often not maintained in practice. In this paper, the authors contend that the Indian Codal provisions relating to concrete cover have to be revised as they do not account for many factors related to minimum concrete cover. Also, some devices and methods to increase the quality of cover are discussed. The authors also stress that just an increase in concrete cover does not ensure durable structure.