Abstract: The hybrid structure or mixed structure means creative building technique in which concrete is combines with other materials with steel, timber, glass etc. for the benefit of building performance. Due to heavy weight of brick, it can be possible to use light-weight materials which can improve the seismic performance of building instead of bricks. It is possible control various seismic parameters using light weight material in hybrid building construction. The wall materials are Timber, AAC block & Brick is used for different wall combinations. The Basic 3 type of model is used in study. The total 54 number of models with different wall system combinations are studied. Calculation of seismic parameters with different wall combinations with different building configurations. The analysis of the models are done ETABS structural tool. The Indian code IS 1893(Part-1):2016 is used for the analysis. The study is concerned with comparison of various seismic parameters of the models.

Keywords: Hybrid structure, seismic parameters, displacement, hybrid frame.